Permit 2690381
4400 122 N ELIZABETH ST · Filed 2026-11-16
Permit Details
| Type | Complaint |
|---|---|
| Work Class | 012 Complaint |
| Status | Active |
| Work Done | Not on file |
| Notes | see email for complaint. |
| Owner | Not on file |
| Contractor | SELF |
| Contractor Phone | N/A |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-11-17 12:22:00 | RDK | C01- Complaint | Complete | wrote violation 2009 IPMC notice need permits for electrical to add new outlets. as required by section 605.1 Installation. . All electrical equipment, wiring and appliances shall be properly installed and maintained in a safe and approved manner. 605.2 receptacles. Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets every laundry area shall contain at least one grounded type receptacle or a receptacle with a ground fault circuit interrupter every bathroom shall contain at least one receptacle any new bathroom receptacle outlets that have ground fault circuit interrupter protection 605.3 luminaries. Every public hall, interior stairway, toilet room shall contain at least one electric luminaire. Section 602 heating facilities 6021 facilities required heating facilities shall be provided in structures as required by this section. 602.2 residential occupancies. Dwellings shall be provided with heating facilities capable of maintaining a room temperature of 68° Fahrenheit 20°C in all habitable rooms bathrooms and toilet rooms based on the winter outdoor design temperature for the local indicated in appendix D of the international plumbing code cooking appliances shall not be used to provide is heating to meet the requirements of this section. 602.3 heat supply. And terms, heat to the occupants thereof September 31st to maintain a 20°C In all habitable rooms, bathrooms and toilet rooms. 505.3 supply. The water supply system shall be installed and maintained to provide a supply of water to plumbing fixtures, devices and opportunities in sufficient volume and at pressures adequately to enable the fixtures to function properly, safely, and free from defects and leaks. |
| 2026-11-20 12:03:00 | RDK | I01- Information | Complete | Added photos. |
Source: Pueblo Regional Building Department. PRBD transitioned to the Southern Colorado Building Department in January 2026 — verify current status at socobd.com. Retrieved November 25, 2026.