4049 PEAK VIEW DR · Filed 2026-11-23

Permit Details

TypeElectrical
Work Class003R Electrical Other | A/C Hookup
StatusActive
Work DoneA/C Hookup
NotesAC Replacement
OwnerJohnny Tonko
ContractorR BUCK HEATING, COOLING, PLUMBING & ELEC
Contractor Phone805-512-3738

Inspection History

DateInspectorTypeResultComment
2026-11-23 03:23:00 JVD E14 - AC Final - Electrical Rejected Replaced an relocated an existing AC condensing unit. Verified smokes/COs and service receptacle. Corrections: 1. Strap the liquitite conduit within 12" of the AC disconnect. 350.30 and 356.30 2. Wirenuts used to join aluminum to copper in junction box must be listed for use with dissimilar metals. 110.14