Permit 2610213
30 BRIARWOOD CIR · Filed 2026-11-18
Permit Details
| Type | Electrical |
|---|---|
| Work Class | 003R Electrical Other | A/C Hookup |
| Status | Active |
| Work Done | A/C Hookup |
| Notes | electrical for ac |
| Owner | tom |
| Contractor | SUPER B ELECTRIC LLC |
| Contractor Phone | 719-669-9628 |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-11-20 11:22:00 | JVD | E14 - AC Final - Electrical | Rejected | Replaced an existing AC condensing unit. Verified service receptacle. Corrections: 1. Smokes/COs to be installed in accordance with the IRC R314 and R315. 2. The GFCI breaker at the disconnect is required to have a neutral connected on the line side of the breaker for proper operation per manufacturer's installation instructions. NEC 110.3B |