Permit 2610106
629 BELMONT AVE · Filed 2026-11-17
Permit Details
| Type | Mechanical |
|---|---|
| Work Class | 004R Mechanical Other | Replace Furnace |
| Status | Active - Flagged |
| Work Done | Replace Furnace |
| Notes | Furnace replacement |
| Owner | Marietta Rotolo |
| Contractor | CLARKS MECHANICAL LLC |
| Contractor Phone | 719-696-9375 |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-11-19 12:51:00 | JJG | M18 - Furnace Final | Rejected | 1-gas shut off valve must be readily accessible, (IFGC 409.1.2 Prohibited locations), 2-vent must terminate according to manufacture specs, 3-need to support R/A plenum so filter door will close and seal correctly, 4-need to support floor at access where cut, 5-cap off existing vent system that is unused, (a $100 re-inspection fee will be assessed) |