1634 WEATHERBY LN · Filed 2026-11-16

Permit Details

TypeMechanical
Work Class004R Mechanical Other | Furnace/AC (No Ductwork)
StatusHas Final
Work DoneFurnace/AC (No Ductwork)
NotesRemove and replace furnace and add ac
OwnerIssac Torres
ContractorFAIRWAY HEATING & COOLING
Contractor Phone719-647-9677

Inspection History

DateInspectorTypeResultComment
2026-11-17 01:23:00 JAM M21 - Furnace/AC Final Rejected does not meet code - $100 reinspection fee has been issued to the address - 3 items; CO alarms are required in the vicinity of sleeping areas, line set insulation needs to be completed above furnace, return air opening (filter door/cover) within 10' of flue vent draft diverter
2026-11-17 01:25:00 JAM M21 - Furnace/AC Final Rejected will accept photos - please recall inspection for final after photos are submitted
2026-11-17 02:36:00 JAM M21 - Furnace/AC Final Final photos accepted of corrections made