Permit 2609921
20 PINERIDGE CT · Filed 2026-11-13
Permit Details
| Type | Electrical |
|---|---|
| Work Class | 003R Electrical Other | A/C Hookup |
| Status | Has Final |
| Work Done | A/C Hookup |
| Notes | Wiring for AC |
| Owner | John Marquez |
| Contractor | ADAMSON ELECTRIC LLC |
| Contractor Phone | 719-429-1215 |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-11-16 10:50:00 | KJG | E14 - AC Final - Electrical | Rejected | Installation of new ac unit and service receptacle. Reinspection fee required for 2nd trip. Corrections 1. GFCI breaker is not functioning. 2. Disconnect needs 36" clearance in front. The line set is run in front of the disconnect. 3. Install the smoke and carbon monoxide detectors per the IRC. IRC-R314 and R315 Need smoke detector in the basement. |
| 2026-11-17 12:18:00 | KJG | E14 - AC Final - Electrical | Final | Corrections complete per previous inspection notes. |