Permit 2609100
2310 STARBOARD LN · Filed 2026-10-26
Permit Details
| Type | Electrical |
|---|---|
| Work Class | 003R Electrical Other | Wire New Structure |
| Status | Active |
| Work Done | Wire New Structure |
| Notes | Electric rough and service |
| Owner | Premier Homes Inc |
| Contractor | J2D ELECTRIC INC |
| Contractor Phone | 719-761-1449 |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-10-26 09:36:00 | KJG | E04 - Rough-in Electrical | Complete | Rough-in new SFR single level slab on grade with attached 2 car garage. |
| 2026-10-26 09:36:00 | KJG | E02 - Service | Rejected | BHE. 200A meter main combo feeding sub in attached garage. Ufer connected in attached garage. Correction 1. Two ground rods or UFER required. (sign-off required for UFER or engineer's letter) NEC-250.53 |
Source: Pueblo Regional Building Department. PRBD transitioned to the Southern Colorado Building Department in January 2026 — verify current status at socobd.com. Retrieved October 27, 2026.