The Pueblo Ledger

Pueblo's public records, made public.

Permit 2608605

1636 LAKE AVE · Filed 2026-10-09

Permit Details

TypePlumbing
Work Class002R Plumbing Other | Water Line Repair/replacement
StatusActive - Flagged
Work DoneWater Line Repair/replacement
NotesUnderground waterline from meter to house
OwnerAaron Marquez
ContractorSUMMIT PLUMBING COMPANY LLC
Contractor Phone719-369-6888

Inspection History

DateInspectorTypeResultComment
2026-10-09 09:54:00 DJM P04 - Water Line Rejected 48in MINIMUM DEPTH. Ordinance. Amen c. 305.4 Where main enters house Approved Material. Table 605.3 Use correct dresser coupling TRACER WIRE INSTALLED ON NON-METALLIC PIPE. State regulation. Must be grounded to galvanized pipe and tracer wire must go inside house. $100 reinspection fee added to permit for 2nd inspection that is required.

Source: Pueblo Regional Building Department. PRBD transitioned to the Southern Colorado Building Department in January 2026 — verify current status at socobd.com. Retrieved October 10, 2026.