Permit 2607895
2521 HOLLYWOOD DR · Filed 2026-09-17
Permit Details
| Type | Mechanical |
|---|---|
| Work Class | 004R Mechanical Other | Install HVAC System |
| Status | Active |
| Work Done | Install HVAC System |
| Notes | New Furnace Install Dryer Vent Exhaust Fans |
| Owner | PARKER |
| Contractor | FLOWORX MECHANICAL, LLC |
| Contractor Phone | 7194064326 |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-09-17 01:54:00 | JJG | M04 - Sheetmetal Rough | Rejected | 1) need 1/4" per ft. rise on furnace vent, (per manufacture specs) 2) Terminate vent, (per manufacture specs) 3) need draft diverter installed on water heater vent connector 4) need fire stops at floor and ceiling penetrations, (no contact to b-vent with foam) |
Source: Pueblo Regional Building Department. PRBD transitioned to the Southern Colorado Building Department in January 2026 — verify current status at socobd.com. Retrieved September 18, 2026.