Permit 2607428
3732 LANCASTER DR · Filed 2026-08-28
Permit Details
| Type | Electrical |
|---|---|
| Work Class | 003R Electrical Other | Electrical Service |
| Status | Active |
| Work Done | Electrical Service |
| Notes | Service upgrade |
| Owner | Mary Hunter |
| Contractor | R BUCK HEATING, COOLING, PLUMBING & ELEC |
| Contractor Phone | 719-544-6670 |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-09-04 12:10:00 | JVD | E02 - Service | Rejected | 200 amp overhead fed service upgrade on a SFR. Verified 2 ground rods and smokes/COs are in place. Correction: The GEC to the cold water line is required to be either connected below the valve or jumpered around the valve. All other work approved. |