Permit 2607423
5527 BELLAGIO WAY · Filed 2026-08-28
Permit Details
| Type | Building |
|---|---|
| Work Class | 706 Res. Finish Bsmnt. | FINISH EXISTING BASEMENT 1670 |
| Status | Active |
| Work Done | FINISH EXISTING BASEMENT 1670 |
| Notes | BASEMENT FINISH AND BATH REISSUE OF 2511208 |
| Owner | THERESA SANDOVAL |
| Contractor | SELF |
| Contractor Phone | N/A |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-09-04 01:57:00 | DDK | B04 - Frame | Complete | See pics of fire blocking at soffit. |
| 2026-08-31 01:31:00 | JVD | E02 - Service | Rejected | Finish remainder of basement. Corrections: 1. Need to meet the wall space requirements of 2', 6' and 12' NEC-210.52A 2. CO & SMOKE DETECTORS TO BE INSTALLED PER IRC. IRC-R314 and R315 3. Make-up all ground wires for inspection. SOCOBD Building policy |
| 2026-09-03 11:16:00 | JVD | E04 - Rough-in Electrical | Complete | Basement finish to include 1 bedroom and a large open area. Corrections from previous inspection have been made. Rough electrical approved. |
Source: Pueblo Regional Building Department. PRBD transitioned to the Southern Colorado Building Department in January 2026 — verify current status at socobd.com. Retrieved September 12, 2026.