Permit 2606855
4820 ROSECREST CT · Filed 2026-08-11
Permit Details
| Type | Electrical |
|---|---|
| Work Class | 003R Electrical Other | A/C Hookup |
| Status | Active - Flagged |
| Work Done | A/C Hookup |
| Notes | AC Swap-Whip Reconnect GFCi WR installed |
| Owner | Laura Wittrup |
| Contractor | GROUNDED ELECTRICAL LLC |
| Contractor Phone | 719-251-9154 |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-08-12 12:49:00 | JVD | E14 - AC Final - Electrical | Rejected | Installed a new mini-split HVAC system. Added a service receptacle. Smokes/CO are in place. Corrections: 1. The AC disconnect is located behind the mini-split in violation of 110.26. 2. Gray is reserved for neutrals only. Must be a phase color. 200.7 3. The receptacle is required to be WR rated. Reinspection fee for 2nd trip added to permit. |