Permit 2606797
917 W 15TH ST · Filed 2026-08-07
Permit Details
| Type | Electrical |
|---|---|
| Work Class | 003 Electrical New | RES 2 ELEC CIRCUITS 200.00 |
| Status | Active |
| Work Done | RES 2 ELEC CIRCUITS 200.00 |
| Notes | RES 2 ELEC CIRCUITS FOR HEAT AND RV HOOK UP |
| Owner | RIOS |
| Contractor | SELF |
| Contractor Phone | N/A |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-08-10 10:03:00 | KJG | E08 - Electric Final | Rejected | 2 new circuits installed, 1 - 20A Heater circuit. and 1 - 30A RV circuit. Corrections 1. Secure EMT within 3' of panel and LB or j-box. 2. NM cable is not listed for use outdoors. Will need to install j-box and change wiring method to THHN/THWN from panel to j-box. 3. RV circuit is using NM cable will need to change to THHN/THWN. 4. RV outlet required to be GFCI protected. |
Source: Pueblo Regional Building Department. PRBD transitioned to the Southern Colorado Building Department in January 2026 — verify current status at socobd.com. Retrieved August 17, 2026.