Permit 2606772

13 DARTMOUTH AVE · Filed 2026-08-06

Permit Details

TypeElectrical
Work Class003R Electrical Other | A/C Hookup
StatusActive
Work DoneA/C Hookup
NotesAC replacement
OwnerJames Hacsi
ContractorNATIVE ELECTRICAL CONTRACTORS
Contractor Phone719-339-7908

Inspection History

DateInspectorTypeResultComment
2026-08-07 02:28:00 JVD E14 - AC Final - Electrical Rejected Installed a new mini-split AC system. Verified service receptacle. Correction: The smokes/COs need to be installed in accordance with the IRC R314 and R315. There needs to be a smoke and CO detector outside each bedroom within 15' of the bedrooms. Also, per NEC 110.3B, the smokes are required to be mounted no closer than 4" from ceiling and no lower than 12" down from the ceiling when mounted on the wall.

Source: Pueblo Regional Building Department. PRBD transitioned to the Southern Colorado Building Department in January 2026 — verify current status at socobd.com. Retrieved August 17, 2026.