The Pueblo Ledger

Pueblo's public records, made public.

Permit 2606668

310 SPRING ST · Filed 2026-08-05

Permit Details

TypeElectrical
Work Class003R Electrical Other | A/C Hookup
StatusActive
Work DoneA/C Hookup
NotesNeed to disconnect the electrical from the old HVAC and connect it to the new HVAC
OwnerNICK MARTINEZ
ContractorJETSON HOME CORPORATION
Contractor Phone888-996-5876

Inspection History

DateInspectorTypeResultComment
2026-08-12 09:34:00 KJG E14 - AC Final - Electrical Rejected Installation of new ac/heat pump and air handler. Corrections 1. Breaker to be sized correctly to the condensing unit label. NEC - 440.12 (A) 2. A convenience receptacle/GFCI to be located within 25' of the condensing unit and on same level. NEC 210.63

Source: Pueblo Regional Building Department. PRBD transitioned to the Southern Colorado Building Department in January 2026 — verify current status at socobd.com. Retrieved August 17, 2026.