Permit 2606666
736 WILSON AVE · Filed 2026-08-05
Permit Details
| Type | Electrical |
|---|---|
| Work Class | 003R Electrical Other | Service |
| Status | Active |
| Work Done | Service |
| Notes | Replacing panel to make room for future heat pump install. Heat pump permit already issued Permit #2606631 |
| Owner | Jason Armijo |
| Contractor | JETSON HOME CORPORATION |
| Contractor Phone | 888-996-5876 |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-08-07 09:45:00 | JVD | E02 - Service | Rejected | 200 amp overhead fed service upgrade on a SFR. Main panel feeds a full sized subpanel in the laundry room. Verified 2 ground rods and smokes/COs are in place. Corrections: 1. Install surge protection. NEC-230.67 2. The cold water bond has been run to the gas line. Need to remove from gas line. Incoming water line is plastic. 3. The subpanel in the laundry/utility room is in violation of 110.26 as there is a shelf above it and a dryer vent line below it. 4. Remove old GEC from subpanel. |
Source: Pueblo Regional Building Department. PRBD transitioned to the Southern Colorado Building Department in January 2026 — verify current status at socobd.com. Retrieved August 17, 2026.