Permit 2606616
2161 TEAL CT · Filed 2026-08-04
Permit Details
| Type | Building |
|---|---|
| Work Class | 706 Res. Finish Bsmnt. | FINISH EXISTING BASEMENT 238 |
| Status | Active |
| Work Done | FINISH EXISTING BASEMENT 238 |
| Notes | SINGLE BEDROOM FINISH IN BASE 238 SF |
| Owner | BRUNNER |
| Contractor | PISCIOTTA CONSTRUCTION LLC |
| Contractor Phone | 719-242-3304 |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-08-12 11:00:00 | RLO | B04 - Frame | Complete | Frame inspection passed good to insulation and air/fire block. Need to make a corrective action on the three mono-post. Need to install the inner 3/8 steel plate 4"x5" between screw jack plate (failing) and the 2 ply LVL beams, will inspected at final inspection not being covered up under this permit. No plumbing nor HVAC permits required using existing HVAC duct for the room finish. Electrical permit only passed RI inspection. |
| 2026-08-07 12:16:00 | KJG | E04 - Rough-in Electrical | Complete | Rough-in NE basement bedroom only. |
Source: Pueblo Regional Building Department. PRBD transitioned to the Southern Colorado Building Department in January 2026 — verify current status at socobd.com. Retrieved August 17, 2026.