Permit 2606413

1602 CONSTITUTION RD · Filed 2026-07-28

Permit Details

TypePlumbing
Work Class002R Plumbing Other | Plumb Remodel
StatusActive
Work DonePlumb Remodel
NotesBasement bathroom was existing repipe 3 piece bath (shower only) Upstairs bathroom was also existing 3 piece (tub and shower combo) Washer box added in basement mechanical floor drain added to bring water heater up to code in mechanical room also 1 existing hosebib (added shutoff Repiped kitchen drain. Everything was existing minus washer box and floor drain
OwnerARGUELLO
ContractorALVARADO PLUMBING SOLUTIONS
Contractor Phone719-287-3924

Inspection History

DateInspectorTypeResultComment
2026-07-29 12:02:00 FDR P08 - Rough-In Plumbing Rejected cleanout required for cloths washer drain. P3005.2 cleanouts required, 2021 IRC. Fixtures located beneath the height of the next upstream manhole are required to run through a backwater valve. P3008.1 backwater valve required. 2021 IRC.
2026-07-31 10:46:00 FDR P08 - Rough-In Plumbing Rejected plumbing from upstairs plumbing cannot run through back water valve. $100 reinspection fee added to permit for third trip.