Permit 2606249
321 JEFFERSON ST · Filed 2026-07-22
Permit Details
| Type | Electrical |
|---|---|
| Work Class | 003R Electrical Other | Electrical Service |
| Status | Has Final |
| Work Done | Electrical Service |
| Notes | Upgrading to a 200 amp service |
| Owner | Elisha Trujillo |
| Contractor | IMPACT SOLAR LLC |
| Contractor Phone | 720-326-8036 |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-07-31 02:11:00 | JVD | E02 - Service | Final | 200 amp overhead fed service upgrade on a SFR. Meter/panel combo. Verified 2 ground rods, cold water bond and smokes/COs. Approved for reconnect. BHE |
| 2026-07-31 14:11:00 | JVD | Z04 Release Sent to Utility | Complete | SFR service upgrade reconnect. -Utility Co: Black Hills; Service type: Overhead; Service size: 200A |
Source: Pueblo Regional Building Department. PRBD transitioned to the Southern Colorado Building Department in January 2026 — verify current status at socobd.com. Retrieved August 03, 2026.