Permit 2606244
2318 THATCHER AVE · Filed 2026-07-21
Permit Details
| Type | Miscellaneous |
|---|---|
| Work Class | 008 Misc. Fee. | SPECIAL INSPECTIONS 110.25 |
| Status | Active |
| Work Done | SPECIAL INSPECTIONS 110.25 |
| Notes | SPECIAL CHANGE IN USE BARBER SHOP NO CONSTRUCTION |
| Owner | AWREDDY BARBER SUPPLY |
| Contractor | SELF |
| Contractor Phone | N/A |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-07-23 09:38:00 | JVD | X07 - Special Inspection | Rejected | 1. There's an open knockout on the deadfront in the main subpanel. 2. Need to GFCI protect all of the receptacles in the bathroom. 3. The receptacle next to the subpanel has reversed polarity. 4. The exit sign is hanging by the wires. 5. There's a blank cover on the ceiling that is hanging down and needs to be reattached to the ceiling. 6. Need to complete the panel schedule. |
| 2026-07-23 09:44:00 | DJM | X07 - Special Inspection | Rejected | Need permit and licensed contractor for water heater that was installed must fix code violations for water heater pan, T&P discharge, bottom fed water heater and need mixing valve on LAV and toilet seat must be open front less cover. |
| 2026-07-23 09:46:00 | TLC | X07 - Special Inspection | Rejected | 1) need licensed contractor to pull permits for mini splits that were installed 2) bath fan in bathroom is not working needs to work with lights |
| 2026-07-23 09:50:00 | RLO | X07 - Special Inspection | Rejected | Building division did pass fire-protection and egress requirements, will need all 3 MEP's permits for corrections, see notes from each disciplines. Photo's to file. Special inspection is rejected till permitted inspections are final out. |
Source: Pueblo Regional Building Department. PRBD transitioned to the Southern Colorado Building Department in January 2026 — verify current status at socobd.com. Retrieved August 03, 2026.