Permit 2606208
2002 E 13TH ST · Filed 2026-07-21
Permit Details
| Type | Electrical |
|---|---|
| Work Class | 003 Electrical New | UPGRADE REPLACE SERVICE 1 0 |
| Status | Has Final |
| Work Done | UPGRADE REPLACE SERVICE 1 0 |
| Notes | RES SERVICE UPGRADE |
| Owner | TORREZ |
| Contractor | ADAMSON ELECTRIC LLC |
| Contractor Phone | 719-429-1215 |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-07-28 01:35:00 | KJG | E02 - Service | Rejected | BHE. OH service upgrade, 200A meter panel combo feeding existing circuits of home. Verified 2 ground rods and water bond is at closest accessible point. Smoke and co detectors are in place. Correction 1. GEC to water needs to be secured independent of EMT. |
| 2026-07-28 04:08:00 | KJG | E02 - Service | Final | Correction made per inspection notes. see pictures uploaded. |
| 2026-07-28 16:07:00 | KJG | Z04 Release Sent to Utility | Complete | Service upgrade -Utility Co: Black Hills; Service type: Overhead; Service size: 200A |
Source: Pueblo Regional Building Department. PRBD transitioned to the Southern Colorado Building Department in January 2026 — verify current status at socobd.com. Retrieved August 03, 2026.