The Pueblo Ledger

Pueblo's public records, made public.

Permit 2606184

4911 BRIARCREST DR · Filed 2026-07-20

Permit Details

TypeElectrical
Work Class003R Electrical Other | A/C Hookup
StatusHas Final
Work DoneA/C Hookup
NotesAC Replacement
OwnerLarry Bontrager
ContractorR BUCK HEATING, COOLING, PLUMBING & ELEC
Contractor Phone805-512-3738

Inspection History

DateInspectorTypeResultComment
2026-07-27 01:59:00 JVD E14 - AC Final - Electrical Rejected Replaced an existing AC condensing unit. Verified smokes/COs and service receptacle. Corrections: 1. Need to install a bushing in the back of the disconnect. 2. Need to reidentify the white conductor in the NM cable in the disconnect to a phase color. 3. Need to strap the liquitite conduit within 12" of the AC disconnect.
2026-07-30 10:05:00 JVD E14 - AC Final - Electrical Final Corrections from previous inspection have been made. Final electrical approved.

Source: Pueblo Regional Building Department. PRBD transitioned to the Southern Colorado Building Department in January 2026 — verify current status at socobd.com. Retrieved August 03, 2026.