224 S UNION AVE · Filed 2026-07-08

Permit Details

TypeMiscellaneous
Work Class008 Misc. Fee. | SPECIAL INSPECTIONS 110.25
StatusActive
Work DoneSPECIAL INSPECTIONS 110.25
NotesSPECIAL INSPECTION HEAVENLY SOUL PLATES
OwnerPUEBLO PATRIARCHS LIMITED
ContractorSELF
Contractor PhoneN/A

Inspection History

DateInspectorTypeResultComment
2026-07-09 09:26:00 JAM X07 - Special Inspection Complete
2026-07-09 09:32:00 FDR X07 - Special Inspection Complete all plumbing is compliant.
2026-07-09 09:50:00 KJG X07 - Special Inspection Rejected There is a cord for equipment in kitchen going through wall into closet. Cords are not allowed to be run through walls. NEC 400.12 Receptacle can be on same side of wall as equipment but will allow if wall has complete pass through for access and cord is not penetrating through a hole in the wall.
2026-07-09 09:59:00 RLO X07 - Special Inspection Rejected Disciplines HVAC/Mechanical and Plumbing passed inspection. Building and electrical are for the same issue need a opening in the closet basement kitchen area, need a top 2x4 installed across the studs and 5/8 sheetrock on all 4 side installed, once completed re-call for building final. This opening is for the cord going through the wall plugging into this outlet, making a passage that is protected for the cord plugin.