Permit 2605702
506 W EVANS AVE · Filed 2026-07-07
Permit Details
| Type | Mechanical |
|---|---|
| Work Class | 004R Mechanical Other | Gas Air Test |
| Status | Has Final |
| Work Done | Gas Air Test |
| Notes | Repair gas line |
| Owner | Deborah Klein |
| Contractor | R BUCK HEATING, COOLING, PLUMBING & ELEC |
| Contractor Phone | 719-544-6670 |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-07-08 12:57:00 | TLC | M06 - Gas Air Test Inspection | Partial | gas air test on csst piping in basement was good,need to tie into gas stubbed through house and test exsiting hard pipe to meter,also need to fix water heater vent into chimney,piping should be 1'' past brick into chimney take pictures before you seal vent to chimney,need carbons installed within 15 foot of bedrooms |
| 2026-07-09 11:35:00 | TLC | Z04 Release Sent to Utility | Complete | red tag work completed,air test good,meter is ready to be unlocked by gas provider -Utility Co: Xcel Energy; Service type: Gas Meter Set; Service size: |
| 2026-07-09 11:35:00 | TLC | M06 - Gas Air Test Inspection | Final | Red tag work completed |
| 2026-07-09 11:35:00 | TLC | Z04 Release Sent to Utility | Complete | red tag work completed,air test good,meter is ready to be unlocked by gas provider -Utility Co: Xcel Energy; Service type: Gas Meter Set; Service size: |
Source: Pueblo Regional Building Department. PRBD transitioned to the Southern Colorado Building Department in January 2026 — verify current status at socobd.com. Retrieved July 11, 2026.