Permit 2605547
60 DUKE ST · Filed 2026-07-01
Permit Details
| Type | Mechanical |
|---|---|
| Work Class | 004R Mechanical Other | Furnace/AC |
| Status | Active |
| Work Done | Furnace/AC |
| Notes | 3 ton electric heat pump installation replacing an existing gas furnace. The gas line will be capped at the removed furnace location. Need to disconnect the electrical from the old HVAC and connect it to the new HVAC. |
| Owner | PHILIP ROMERO |
| Contractor | JETSON HOME CORPORATION |
| Contractor Phone | 888-996-5876 |
Inspection History
| Date | Inspector | Type | Result | Comment |
|---|---|---|---|---|
| 2026-07-08 10:39:00 | TLC | M21 - Furnace/AC Final | Rejected | need to make repairs to transition attached to air handler needs to be mechanically fastend per SMANA,also need 1/8'' grade on condensation drain must be over floor drain,need carbon monoxide detectors within 15 foot of bedrooms,next failed inspection will result in a 100 dollar reinspection fee |