Marriott (Courtyard Pueblo Downtown)- Pool
110 W City Center Dr, Pueblo CO 81003 · Recreational Water
Score History
Lower scores are better. Score bands: 0–49 Pass, 50–109 Re-Inspection Required, 110+ Closed.
Inspection History
2026-11-19 Not graded 0 violation(s)
No violations recorded for this inspection.
View official record on PDPHE portal →
Source: PDPHE, retrieved November 25, 2026.
2026-11-10 Not graded 2 violation(s)
None — 10: pH was tested at a 6.91
None — 52: No Certified Pool operator is employed or servicing the facility
View official record on PDPHE portal →
Source: PDPHE, retrieved November 25, 2026.
2026-11-05 Not graded 2 violation(s)
None — 21: Closure conditions still persists.
None — 40: Controllers are still not functioning properly.
View official record on PDPHE portal →
Source: PDPHE, retrieved November 25, 2026.
2026-10-27 Not graded 10 violation(s)
4.5.19.1.1 — Missing deck depth marks on shallow and deep end.
Corrective action: All no diving symbols are present.
6.6.3.1 — The following has been determined to be a public health hazard requiring immediate correction or immediate closure of the aquatic venue: 1.) HVAC system and ventilation system is not working properly causing for condensation, moisture to form causing for mold to grow in the grout of the tiles.
Corrective action: Facility was instructed to put a work order in for this HVAC and ventilation systems, and to regrout areas of concern around the whole spa. 2.) Pool is not being tested every 2 hours like instructed. 3.) Observed split chlorine in the pump room. Spoke with person in charge about proper cleaning of this.
4.5.6.6 — Grab rails are not anchored securely.
Corrective action: Observed loose grab rail ladder on the pool.
5.8.5.2.2.1 — Signage is not provided at the aquatic venue or each aquatic venue, as necessary, which clearly identifies the following: 1) First aid location(s), and 2) Emergency telephone(s) or approved communication system or device.
5.7.3.5.1.4 — Chemical feed equipment is not maintained in good working condition.
Corrective action: Chemical feeder/controller were not working during inspection. Per person in charge ecolab has been called for this item.
5.7.3.7.1 — Automated controllers are not calibrated per manufacturer directions and was not functioning during time of inspection.
Corrective action: Per person in charge ecolab has been called to fix this item.
5.9.1.11 — Chemicals are not being stored properly in the chemical storage room.
Corrective action: Observed chlorine pucks being stored on top of the lids. Spoke with person in charge about proper chemical storage
6.4.1.6 — Daily, or as often as required, monitoring and testing records do not include the following, where applicable: 1) pH level, 2) disinfectant residuals, 3) Combined chlorine concentrations, 4) Operating pressures of water recirculation pumps and filters or the corresponding flow rate from flow meter readings, 5) CYA levels, if used, 6) Maintenance and malfunctioning of equipment, including dates and time of all equipment calibration including WQTDs 7) Dates of challenge testing of the chemical feeder interlock system as outlined in MAHC 5.7.3.5.1.4.1, 8) If heated, aquatic venue water temperature, 9) The time of filter backwash or cleaning, 10) Calcium hardness, 11) Total alkalinity, 12) Saturation index, 13) Microbiological testing, if applicable, dates/times samples were taken and results, 14) Any equipment failure, power outage, or error resulting in the interruption of the circulation, filtration, or disinfection systems for more than 1 hour, 15) secondary disinfection systems, where used, as outlined in MAHC 5.7.3.7.7 and 5.7.3.7.8.
Corrective action: Testing records lacked certain dates and are not being tested every 2 hours as instructed.
6.4.1.5 — A chemical inventory log is not maintained on site to provide a list of chemicals used in the aquatic venue water and surrounding deck that could result in water quality issues, chemical interactions, or patron exposure.
Corrective action: Facility does not have a chemical inventory.
6.3.4.5.1 — A written EAP was not developed, maintained, and updated as necessary for the aquatic facility to include at a minimum: 1) A diagram of the aquatic facility; 2) A list of emergency telephone numbers; 3) The location of first aid kit and other rescue equipment (BVM, AED, if provided, backboard, etc.); 4) An emergency response plan for accidental chemical release; and 5) A fecal/vomit/blood contamination response plan as outlined in MAHC 6.5.1.; 6) Outline types of emergencies and imminent health hazards, as per MAHC 6.6.3; 7) Outline the methods of communication between responders, emergency services, and patrons; 8) Identify each anticipated responder; 9) Outline the tasks of each responder; 10) Identify required equipment for each task; and 11) Emergency closure requirements.
Corrective action: Item was not able to be identified during inspection.
View official record on PDPHE portal →
Source: PDPHE, retrieved November 25, 2026.
2026-02-26 Not graded Violation details not available
Full violation detail for this inspection hasn't been retrieved yet.
View official record on PDPHE portal →
Source: PDPHE, retrieved November 25, 2026.
2025-10-21 Not graded Violation details not available
Full violation detail for this inspection hasn't been retrieved yet.
View official record on PDPHE portal →
Source: PDPHE, retrieved November 25, 2026.