La Quinta Inns & Suites-Pool

4801 N Elizabeth St, Pueblo CO 81008 · Recreational Water

Score History

This program does not receive a numeric score.

Inspection History

2026-06-10 Not graded 19 violation(s)
6.6.3.1 — Missing symbols and required numbers on deck and vertical wall.
Corrective action: Numbers and Symbol required at every depth change on deck, as well as not being spaced more than 25' apart. Vertical pool wall requires depth number at same locations.
6.6.3.1 — No controllers installed for pH or chlorine.
Corrective action: pH does not have a feeder installed. Manual addition of acid is being utilized.
None — 21: Testing requirements are not being met in conjunction to manual addition of chemicals. While manual addition is occurring, the pH and FC must be tested every 2 hours while the pool is open.
5.6.9.3.4 — Deck is in disrepair, including loose handrail.
5.7.1.4.5 — Leaves and debris in both skimmers
5.8.5.2.1.2 — The aquatic facility or aquatic venue, as necessary, does not have a functional telephone or other communication device that is hard wired and capable of directly dialing 911 or function as the emergency notification system.
5.8.5.2.3.1 — supplies not available or no sign present in pool area
None — 33: missing all required signs except pool rules
5.7.3.6.1.1 — reagent expired for pH, faded dates on FC reagents cannot be confirmed
5.7.3.5.1 — Feeder not present for pH undefined
4.7.3.2.8.1 — controller not present for pH or FC
5.9.1.13 — Chemicals are being stored in mechanical room.
Corrective action: Also observed open containers in mechanical room.
None — 46: 5.9.1.10
5.10.4.5 — No diaper stations installed.
Corrective action: Once installed in lobby, signage must be placed in the pool area to direct patrons to the stations.
6.1.1.2.1 — No Certified Pool Operator certificate available.
None — 54: 6.4.2.3.2
5.7.5.3 — Missing several days of no logs, days with testing only once also present
6.4.1.5 — No inventory log present
6.3.4.5.6 — A written EAP was not developed, maintained, and updated as necessary for the aquatic facility to include at a minimum: 1) A diagram of the aquatic facility; 2) A list of emergency telephone numbers; 3) The location of first aid kit and other rescue equipment (BVM, AED, if provided, backboard, etc.); 4) An emergency response plan for accidental chemical release; and 5) A fecal/vomit/blood contamination response plan as outlined in MAHC 6.5.1.; 6) Outline types of emergencies and imminent health hazards, as per MAHC 6.6.3; 7) Outline the methods of communication between responders, emergency services, and patrons; 8) Identify each anticipated responder; 9) Outline the tasks of each responder; 10) Identify required equipment for each task; and 11) Emergency closure requirements.
View official record on PDPHE portal →

Source: PDPHE, retrieved August 17, 2026.